Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

April 26, 2010 | Mark Paradies

Monday Accident & Lessons Learned: OGP Safety Alert #218 – Compressor Failure & Fire

OGP SAFETY ALERT NO. 218:

COMPRESSOR FAILURE AND SUBSEQUENT FIRE ON FACILITY

Country: AUSTRALIA

Location: OFFSHORE : Floating Production Storage & Offloading Unit

A high pressure gas compressor experienced a catastrophic failure during start up on an FPSO (Floating Production Storage and Offload) vessel. This failure caused a hydrocarbon gas release that auto ignited, resulting in a local jet fire at the compressor and a second fire within the gas turbine enclosure. Fortunately no personnel were injured during the incident.

Centrifugal gas compressors are widely utilised on production facilities within Australian waters. They are typically used to compress gas required for export or well re-injection. A typical gas compressor configuration consists of 1st LP (low pressure) stage, 2nd IP (intermediate pressure) stage and 3rd HP (high pressure) stage.

What could go wrong?

  • High reliance on a single piece of safety critical equipment – for example, an instrument
  • Inadequate commissioning of the compressor’s control systems
  • Inadequate protection systems in place to protect compressors from operating outside design limitations
  • Personnel overwhelmed by ‘Nuisance’ Alarms’ can overlook significant
  • Personnel not trained for site specific equipment operation
  • Inadequate management of safety device ‘inhibits’
  • Inadequate commissioning of fire protections systems

Key Lessons:

  • Ensure commissioning activities are correctly undertaken and verified by competent persons.
  • Ensure control room operations personnel have the required competence and training for their specific control system and type of compressor on location.
  • Ensure control room operators are not overloaded by ‘nuisance’ alarms by ensuring effective alarm management through alarm rationalisation.
  • Any overrides on safety controls should be controlled and be properly risk assessed.
  • Repetitive alarms need to be properly investigated and resolved.
  • Ensure effective management of procedural controls by compliance monitoring.
  • Wherever possible minimise dependence on operators in safeguarding the compressor.
  • Develop the compressor’s safe guard system to ensure a fail safe design.
  • Consider the impact of an instrument failure in machine control or protection systems, particularly if fail-to-danger is undetected.

Who is responsible?

Under provisions of the Offshore Petroleum and Greenhouse Gas Storage Act 2006, operators of facilities have a duty of care to ensure that plant and equipment at the facility are safe and without risk to health. Suppliers of plant have a duty to ensure that plant, when properly used, is safe and without risk to health.